Thermal resistance R vs U-value
What is the difference between an R-value and a U-value?
Thermal resistance R (m²K/W) is the manufacturer's declared resistance to heat flow through the whole laminate — board and insulation together. Higher is better. R belongs to the laminate; a wall's U-value depends on the whole build-up and is calculated separately to BS EN ISO 6946.
The two numbers are easy to confuse because they measure the same thing from opposite ends. R says how well a layer resists heat flow; U says how fast heat leaks through a complete element. One belongs to a product, the other to a wall — the same split as reaction to fire (a board property) and fire resistance (a system property).
R belongs to a layer
Thermal resistance R, in m²K/W, describes one layer of a given thickness. Higher is better. For a single uniform material it is the thickness divided by the material’s thermal conductivity λ, so a thicker layer or a better insulant both raise it.
A thermal laminate declares R for the whole product — the plasterboard facing and the insulation together. That is the right figure for comparing one laminate against another, because it already accounts for the thickness of the insulant.
U belongs to the wall
A U-value, in W/m²K, is the rate of heat loss through a complete element such as an external wall. Lower is better. It is built up from every layer in the wall plus the resistances of the air films on each surface:
- Add the R of every layer: the masonry or substrate, any cavity, the adhesive dabs or air gap behind the lining, the laminate itself, and any plaster or finish.
- Add the inside and outside surface resistances, which are standard values.
- Take the reciprocal of the total to get the U-value, then apply corrections — for example for mechanical fixings that bridge the insulation and for air gaps.
That calculation follows BS EN ISO 6946. Because it depends on everything else in the wall, the same laminate gives a different U-value on a solid brick wall than on a block cavity wall.
Why drywallDB shows R and never a U-value
A manufacturer can declare R for its laminate because R is a property of the product. Nobody can declare a U-value for a laminate on its own, because the U-value belongs to a wall that the manufacturer has never seen. drywallDB only shows values it can cite, so it shows each laminate’s declared R and stops there.
To meet a U-value target, use the wall’s own calculation: manufacturers offer U-value calculation services for their products, and a qualified calculation to BS EN ISO 6946 does the same job. Upgrading the insulation of an existing wall can also bring Building Regulations (Part L) requirements with it, so check with building control early.
drywallDB’s comparison rules reflect the same split: laminates are compared on declared R, insulant and thickness, and every laminate comparison and document carries a note that the wall’s U-value is calculated separately.
Frequently asked questions
- Can I convert a laminate’s R into a U-value?
- Not on its own. A U-value needs the R of every other layer in the wall, the surface resistances and corrections for fixings and air gaps. The laminate’s R is one input to that calculation, not the answer.
- Is a higher R always better?
- For insulation, yes — higher R means more resistance to heat flow. But more R usually means a thicker laminate, which costs room space and affects window reveals, sockets and fixings, so the useful question is how much R fits in the depth available.
- Why do two laminates of the same thickness declare different R?
- Because the insulants differ. PIR typically insulates better per millimetre than XPS, and XPS better than EPS, so at the same overall thickness a PIR laminate usually declares a higher R.
- Who can give me a U-value for my wall?
- The laminate manufacturer’s technical or U-value calculation service, or a qualified energy assessor or designer working to BS EN ISO 6946. Give them the full build-up, not just the laminate.